Synchronize Operational Metrics configuration settings rules

Operational Metrics configuration settings rules contain user specified values that override default values that currently exist on Operational Metrics MID Servers. To take effect, the Operational Metrics MID Servers must be synchronized with the updated set of configuration settings rules.

Before you begin

Role required: evt_mgmt_admin

About this task

You can manually initiate a synchronization to immediately apply the updates on all Operational Metrics MID Servers. Or, you can rely on a system job, that runs on an hourly recurring schedule, checking for updates to the metric configuration rules. If it is determined that there are updates, the system job sends these updates to the Operational Metrics MID Servers.

Procedure

  1. Navigate to Event Management > Operational Metrics > Metric Config Rules.
  2. On the Metric Configuration Rules pane, click Sync to MID.

What to do next

  • Verify that all Operational Metrics MID Servers have been synchronized with the updated set of configuration settings rules:
    1. Navigate to Output and Artifacts > ECC Queue.
    2. In the Queues pane, search the Topics column for MetricConfigProbe.
    3. Check the Agent column and verify that all MID Servers are updated.